| Product | Style | Ratings | Configuration |
|---|---|---|---|
| Heat Exchanger | Shell & Tube | 300°F | One Pass |
-Download Datasheet
Note: Unit pictured is representative of standard unit and may not exactly depict p/n 5-155-08-081-003 as shown on this page.
Configured for compressed air aftercooling, this configuration carries the removable straight-tube bundle construction that defines the ACA aftercooler range. Hot compressed air enters the tubes while cooling water counterflows through the shell, condensing moisture for removal downstream. Physically, the unit runs a 8-inch shell, 72-inch shell length in a 1-pass arrangement. It carries 1/4-inch O.D. tubes. As furnished, materials include cast iron bonnets, steel shell, copper tubes, and steel tubesheets. On the ratings side, expect 300°F maximum temperature. This build is designated 5-155-08-081-003. Installations range across compressed air dryer pre-cooling, compressor discharge aftercooling, and moisture and oil removal from plant air. A floating rear tubesheet lets the bundle expand freely and pull for cleaning, and full-size air connections hold pressure drop down.