| Product | Style | Ratings | Configuration |
|---|---|---|---|
| Heat Exchanger | Shell & Tube | 150 PSI / 375°F | Two Pass |
-Download Datasheet
Note: Unit pictured is representative of standard unit and may not exactly depict p/n TCS-1478 as shown on this page.
The TCS/TCW tank heater platform pairs a two-pass U-bend bundle with proven shell-side baffling, and this configuration applies that design to in-tank heating with steam in the tubes. The bundle mounts through a collar in the tank wall and heats the surrounding fluid by natural convection. Physically, the unit runs a 14-inch shell, 78-inch shell length, and roughly 79-1/2 inches overall in a 2-pass arrangement. That works out to about 190 square feet of heat transfer surface on 3/4-inch O.D. tubes. Standard construction uses cast iron or brass bonnets, steel shell, copper tubes, and steel or brass tubesheets. The unit is rated for 150 PSI on the shell side, 150 PSI on the tube side, and 375°F maximum temperature. This build is designated TCS-1478.