| Product | Style | Ratings | Configuration |
|---|---|---|---|
| Heat Exchanger | Shell & Tube | 150 PSI / 375°F | Two Pass |
-Download Datasheet
Note: Unit pictured is representative of standard unit and may not exactly depict p/n 5-268-10-060-001 as shown on this page.
Configured for high-temperature water heating, this configuration carries the removable U-tube bundle construction that defines the HTWU range. High-temperature water flows through the tube side, so the heads rather than the shell set the pressure limit. Physically, the unit runs a 10-inch shell, 60-inch shell length, and roughly 65-3/8 inches overall in a 2-pass arrangement. That works out to about 71 square feet of heat transfer surface on 3/4-inch O.D. tubes. That combination is cataloged as 5-268-10-060-001. Material selection covers cast iron bonnets, steel shell, copper tubes, and steel tubesheets. Operating limits are 150 PSI on the shell side, 400 PSI on the tube side, and 375°F maximum temperature.