| Product | Style | Ratings | Configuration |
|---|---|---|---|
| Heat Exchanger | Shell & Tube | 150 PSI / 375°F | Two Pass |
-Download Datasheet
Note: Unit pictured is representative of standard unit and may not exactly depict p/n 5-268-08-048-001 as shown on this page.
A removable U-tube bundle gives 5-268-08-048-001 the thermal and mechanical margin expected of HTWU equipment in high-temperature water heating. High-temperature water flows through the tube side, so the heads rather than the shell set the pressure limit. Its envelope centers on a 8-inch diameter shell, 48-inch shell length, and roughly 53-1/8 inches overall in a 2-pass arrangement. That works out to about 32 square feet of heat transfer surface on 3/4-inch O.D. tubes. Material selection covers cast iron bonnets, steel shell, copper tubes, and steel tubesheets. The unit is rated for 150 PSI on the shell side, 400 PSI on the tube side, and 375°F maximum temperature. Common applications are high-temperature hot water distribution, converter duty on HTHW loops, and industrial process heating.