| Product | Style | Ratings | Configuration |
|---|---|---|---|
| Heat Exchanger | Shell & Tube | 150 PSI / 300°F | Four Pass |
-Download Datasheet
Note: Unit pictured is representative of standard unit and may not exactly depict p/n 5-266-04-072-002 as shown on this page.
This configuration is a SU/WU unit built on a removable U-tube bundle for liquid-to-liquid heating and cooling. Pumped boiler water circulates through the baffled shell against the tube-side fluid. The configuration measures 4 inches across the shell, 72-inch shell length, and roughly 76-7/8 inches overall in a 4-pass arrangement. That works out to about 13.9 square feet of heat transfer surface on 3/4-inch O.D. tubes. Standard construction uses cast iron bonnets, steel shell, copper tubes, and brass tubesheets. Operating limits are 150 PSI on the shell side, 150 PSI on the tube side, and 300°F maximum temperature. Installations range across condensate cooling, hydronic HVAC converters, and pool and storage-tower heating. This build is designated 5-266-04-072-002.