| Product | Style | Ratings | Configuration |
|---|---|---|---|
| Heat Exchanger | Shell & Tube | 150 PSI / 300°F | Six Pass |
-Download Datasheet
Note: Unit pictured is representative of standard unit and may not exactly depict p/n 5-265-12-096-003 as shown on this page.
Built around a removable U-tube bundle, this configuration delivers liquid-to-liquid heating and cooling for demanding service. Pumped boiler water circulates through the baffled shell against the tube-side fluid. Its envelope centers on a 12-inch diameter shell, 96-inch shell length, and roughly 104-1/2 inches overall in a 6-pass arrangement. That works out to about 139 square feet of heat transfer surface on 3/4-inch O.D. tubes. The build specifies cast iron bonnets, steel shell, copper tubes, and steel tubesheets. On the ratings side, expect 150 PSI on the shell side, N/A on the tube side, and 300°F maximum temperature. This build is designated 5-265-12-096-003. Installations range across pool and storage-tower heating, oil cooling and snow melting, and condensate cooling.