| Product | Style | Ratings | Configuration |
|---|---|---|---|
| Heat Exchanger | Shell & Tube | 150 PSI / 375°F | One Pass |
-Download Datasheet
Note: Unit pictured is representative of standard unit and may not exactly depict p/n 5-151-16-180-001 as shown on this page.
Configured for general industrial liquid-to-liquid heat transfer, 5-151-16-180-001 carries the removable straight-tube bundle construction that defines the OC straight tube range. An internally packed floating rear tubesheet absorbs differential expansion, and the bundle pulls for straight-through mechanical tube cleaning. The configuration measures 16 inches across the shell, 180-inch shell length, and roughly 198 inches overall in a 1-pass arrangement. That works out to about 711 square feet of heat transfer surface on 5/8-inch O.D. tubes. The build specifies cast iron bonnets, steel shell, copper tubes, and steel tubesheets. The unit is rated for 150 PSI on the shell side, 150 PSI on the tube side, and 375°F maximum temperature. Typical duty includes chemical and refinery duty, oil and quench cooling, and process heating and cooling.