| Product | Style | Ratings | Configuration |
|---|---|---|---|
| Heat Exchanger | Shell & Tube | 150 PSI / 375°F | Six Pass |
-Download Datasheet
Note: Unit pictured is representative of standard unit and may not exactly depict p/n 5-267-10-048-003 as shown on this page.
Built around a double-wall U-tube bundle, this configuration delivers liquid-to-liquid transfer with cross-contamination protection for demanding service. Each tube is vented to atmosphere through a diamond-pattern air gap, so a failure in either wall reports itself outside the unit. The configuration measures 10 inches across the shell, 48-inch shell length in a 6-pass arrangement. It carries 3/4-inch O.D. tubes. As furnished, materials include cast iron bonnets, steel shell, copper (double wall) tubes, and naval brass tubesheets. The unit is rated for 150 PSI on the shell side, 125 PSI on the tube side, and 375°F maximum temperature. Installations range across potable water heating and cooling, domestic water systems under double-wall codes, and process cooling where mixing cannot be tolerated. This build is designated 5-267-10-048-003.