| Product | Style | Ratings | Configuration |
|---|---|---|---|
| Heat Exchanger | Shell & Tube | 300 PSI / 300°F | One Pass |
-Download Datasheet
Note: Unit pictured is representative of standard unit and may not exactly depict p/n 5-160-04-036-001 as shown on this page.
Built around a fixed-tubesheet bundle, this configuration delivers compact liquid cooling in corrosive service for demanding service. It shares the compact CHX envelope while targeting service that would attack a standard cooler. The configuration measures 4 inches across the shell, 36-inch shell length, and roughly 40 inches overall in a 1-pass arrangement. That works out to about 21.2 square feet of heat transfer surface on 5/8-inch O.D. tubes. That combination is cataloged as 5-160-04-036-001. As furnished, materials include cast iron bonnets, steel shell, copper tubes, and brass tubesheets. Design ratings run to 300 PSI on the shell side, 150 PSI on the tube side, and 300°F maximum temperature. Typical duty includes deionized and treated water cooling, mechanical seal cooling, and chemical and food process cooling.