A fixed-tubesheet bundle gives 5-030-08-036-003 the thermal and mechanical margin expected of CHX compact equipment in compact liquid cooling. Small-diameter tubes pack maximum surface into a short shell, keeping the mounting footprint tight. Its envelope centers on a 8-inch diameter shell, 36-inch shell length, and roughly 42-1/2 inches overall in a 2-pass arrangement. That works out to about 62 square feet of heat transfer surface on 3/4-inch O.D. tubes. Material selection covers cast iron bonnets, brass shell, copper tubes, and brass tubesheets. Operating limits are 300 PSI on the shell side, 150 PSI on the tube side, and 300°F maximum temperature. Common applications are engine jacket water cooling, injection molding machine cooling, and mechanical seal cooling.