| Product | Style | Ratings | Configuration |
|---|---|---|---|
| Heat Exchanger | Shell & Tube | 300 PSI / 300°F | One Pass |
-Download Datasheet
Note: Unit pictured is representative of standard unit and may not exactly depict p/n 5-030-08-036-002 as shown on this page.
This configuration is a CHX compact unit built on a fixed-tubesheet bundle for compact liquid cooling. Small-diameter tubes pack maximum surface into a short shell, keeping the mounting footprint tight. Its envelope centers on a 8-inch diameter shell, 36-inch shell length, and roughly 43 inches overall in a 1-pass arrangement. That works out to about 62 square feet of heat transfer surface on 3/4-inch O.D. tubes. As furnished, materials include cast iron bonnets, brass shell, copper tubes, and brass tubesheets. Design ratings run to 300 PSI on the shell side, 150 PSI on the tube side, and 300°F maximum temperature. Installations range across hydraulic and lube oil cooling, mechanical seal cooling, and injection molding machine cooling. This build is designated 5-030-08-036-002.