| Product | Style | Ratings | Configuration |
|---|---|---|---|
| Heat Exchanger | Shell & Tube | 1000°F | Removable Straight-Tube Bundle |
-Download Datasheet
Note: Unit pictured is representative of standard unit and may not exactly depict p/n 5-153-10-111-005 as shown on this page.
For water-cooled gas cooling, the GC gas cooler line offers a removable straight-tube bundle design; this configuration sits within that range. Hot gas passes through the tubes against cooling water in the baffled shell, and the unit shares the removable-bundle construction of the OC series. Dimensionally it is a 10-inch shell unit, 111-inch shell length. It carries 5/8-inch O.D. tubes. As furnished, materials include cast iron bonnets, steel shell, copper tubes, and steel tubesheets. On the ratings side, expect 1000°F maximum temperature. This build is designated 5-153-10-111-005. Installations range across process gas cooling, blower and vapor cooling duty, and compressor discharge gas cooling. Small-diameter tubing maximizes surface in a given shell, and alternate tube alloys are available for corrosive gas streams.