| Product | Style | Ratings | Configuration |
|---|---|---|---|
| Heat Exchanger | Shell & Tube | 1000°F | Removable Straight-Tube Bundle |
-Download Datasheet
Note: Unit pictured is representative of standard unit and may not exactly depict p/n 5-153-08-063-002 as shown on this page.
For water-cooled gas cooling, the GC gas cooler line offers a removable straight-tube bundle design; this configuration sits within that range. Hot gas passes through the tubes against cooling water in the baffled shell, and the unit shares the removable-bundle construction of the OC series. The configuration measures 8 inches across the shell, 63-inch shell length. It carries 5/8-inch O.D. tubes. That combination is cataloged as 5-153-08-063-002. The build specifies cast iron bonnets, steel shell, steel tubes, and steel tubesheets. Design ratings run to 1000°F maximum temperature. Installations range across process gas cooling, compressor discharge gas cooling, and blower and vapor cooling duty. Small-diameter tubing maximizes surface in a given shell, and alternate tube alloys are available for corrosive gas streams.