| Product | Style | Ratings | Configuration |
|---|---|---|---|
| Heat Exchanger | Shell & Tube | 300°F | One Pass |
-Download Datasheet
Note: Unit pictured is representative of standard unit and may not exactly depict p/n 5-005-10-050-003 as shown on this page.
The ACFR aftercooler platform pairs a fixed-tubesheet bundle with proven shell-side baffling, and 5-005-10-050-003 applies that design to compressed air aftercooling. Compressed air passes through the tubes against cooling water in the baffled shell, and the tube interiors clean easily from either end. Shell dimensions vary by size within this configuration in a 1-pass arrangement. It carries 1/4-inch O.D. tubes. Material selection covers cast iron bonnets, steel shell, copper tubes, and steel tubesheets. On the ratings side, expect 300°F maximum temperature. Installations range across compressor discharge aftercooling, moisture and oil removal from plant air, and small and mid-size compressor packages. Steel tubesheets and baffles with 1/4-inch copper tubes keep the assembly compact, and the fixed-tubesheet design holds overall length within 50 inches.