| Product | Style | Ratings | Configuration |
|---|---|---|---|
| Heat Exchanger | Shell & Tube | 150 PSI / 375°F | Two Pass |
-Download Datasheet
Note: Unit pictured is representative of standard unit and may not exactly depict p/n 5-277-06-060-001 as shown on this page.
Configured for in-tank heating with boiler water in the tubes and cross-contamination protection, 5-277-06-060-001 carries the double-wall two-pass U-bend bundle construction that defines the Diamondback tank heater range. The vented air gap between tube walls gives a visible telltale leak rather than allowing boiler water and tank contents to mix. Physically, the unit runs a 6-inch shell in a 2-pass arrangement. It carries 3/4-inch O.D. tubes. As furnished, materials include cast iron bonnets, steel shell, and copper (double wall) tubes. Operating limits are 150 PSI on the shell side, 150 PSI on the tube side, and 375°F maximum temperature. Installations range across institutional and health care water storage, potable water storage tanks, and glycol-fed storage heating.