| Product | Style | Ratings | Configuration |
|---|---|---|---|
| Heat Exchanger | Shell & Tube | 150 PSI / 375°F | Two Pass |
-Download Datasheet
Note: Unit pictured is representative of standard unit and may not exactly depict p/n 5-272-12-078-001 as shown on this page.
Configured for in-tank heating with steam in the tubes and cross-contamination protection, 5-272-12-078-001 carries the double-wall two-pass U-bend bundle construction that defines the Diamondback tank heater range. The vented air gap between tube walls gives a visible telltale leak rather than allowing tank contents and steam to mix. Dimensionally it is a 12-inch shell unit, 78-inch shell length in a 2-pass arrangement. It carries 3/4-inch O.D. tubes. Standard construction uses cast iron bonnets, steel shell, and copper (double wall) tubes. Operating limits are 150 PSI on the shell side, 125 PSI on the tube side, and 375°F maximum temperature. Typical duty includes domestic hot water storage under double-wall codes, food-grade process tanks, and institutional water storage.