| Product | Style | Ratings | Configuration |
|---|---|---|---|
| Heat Exchanger | Shell & Tube | 150 PSI / 375°F | Two Pass |
-Download Datasheet
Note: Unit pictured is representative of standard unit and may not exactly depict p/n 5-272-06-096-001 as shown on this page.
For in-tank heating with steam in the tubes and cross-contamination protection, the Diamondback tank heater line offers a double-wall two-pass U-bend bundle design; 5-272-06-096-001 sits within that range. The vented air gap between tube walls gives a visible telltale leak rather than allowing tank contents and steam to mix. Dimensionally it is a 6-inch shell unit in a 2-pass arrangement. It carries 3/4-inch O.D. tubes. Material selection covers cast iron bonnets, steel shell, and copper (double wall) tubes. The unit is rated for 150 PSI on the shell side, 150 PSI on the tube side, and 375°F maximum temperature. The series sees regular use in potable water storage tanks, domestic hot water storage under double-wall codes, and food-grade process tanks.