| Product | Style | Ratings | Configuration |
|---|---|---|---|
| Heat Exchanger | Shell & Tube | 150 PSI / 375°F | Two Pass |
-Download Datasheet
Note: Unit pictured is representative of standard unit and may not exactly depict p/n 5-272-06-036-001 as shown on this page.
5-272-06-036-001 is a Diamondback tank heater unit built on a double-wall two-pass U-bend bundle for in-tank heating with steam in the tubes and cross-contamination protection. The vented air gap between tube walls gives a visible telltale leak rather than allowing tank contents and steam to mix. The configuration measures 6 inches across the shell in a 2-pass arrangement. It carries 3/4-inch O.D. tubes. Material selection covers cast iron bonnets, steel shell, and copper (double wall) tubes. On the ratings side, expect 150 PSI on the shell side, 150 PSI on the tube side, and 375°F maximum temperature. Typical duty includes potable water storage tanks, food-grade process tanks, and institutional water storage.