| Product | Style | Ratings | Configuration |
|---|---|---|---|
| Heat Exchanger | Shell & Tube | 150 PSI / 300°F | Two Pass |
-Download Datasheet
Note: Unit pictured is representative of standard unit and may not exactly depict p/n 5-265-10-096-001 as shown on this page.
Built around a removable U-tube bundle, this configuration delivers liquid-to-liquid heating and cooling for demanding service. Pumped boiler water circulates through the baffled shell against the tube-side fluid. The configuration measures 10 inches across the shell, 96-inch shell length, and roughly 101 inches overall in a 2-pass arrangement. That works out to about 116 square feet of heat transfer surface on 3/4-inch O.D. tubes. Material selection covers cast iron bonnets, steel shell, copper tubes, and steel tubesheets. The unit is rated for 150 PSI on the shell side, 125 PSI on the tube side, and 300°F maximum temperature. Common applications are pool and storage-tower heating, oil cooling and snow melting, and condensate cooling. This build is designated 5-265-10-096-001.