| Product | Style | Ratings | Configuration |
|---|---|---|---|
| Heat Exchanger | Shell & Tube | 150 PSI / 375°F | Two Pass |
-Download Datasheet
Note: Unit pictured is representative of standard unit and may not exactly depict p/n 5-151-18-120-002 as shown on this page.
For general industrial liquid-to-liquid heat transfer, the OC straight tube line offers a removable straight-tube bundle design; this configuration sits within that range. An internally packed floating rear tubesheet absorbs differential expansion, and the bundle pulls for straight-through mechanical tube cleaning. Dimensionally it is a 18-inch shell unit, 120-inch shell length, and roughly 136-1/2 inches overall in a 2-pass arrangement. That works out to about 604 square feet of heat transfer surface on 5/8-inch O.D. tubes. That combination is cataloged as 5-151-18-120-002. Material selection covers cast iron bonnets, steel shell, copper tubes, and steel tubesheets. Operating limits are 150 PSI on the shell side, 150 PSI on the tube side, and 375°F maximum temperature.