| Product | Style | Ratings | Configuration |
|---|---|---|---|
| Heat Exchanger | Shell & Tube | 150 PSI / 375°F | Two Pass |
-Download Datasheet
Note: Unit pictured is representative of standard unit and may not exactly depict p/n 5-151-16-096-002 as shown on this page.
The OC straight tube platform pairs a removable straight-tube bundle with proven shell-side baffling, and this configuration applies that design to general industrial liquid-to-liquid heat transfer. An internally packed floating rear tubesheet absorbs differential expansion, and the bundle pulls for straight-through mechanical tube cleaning. Physically, the unit runs a 16-inch shell, 96-inch shell length, and roughly 111-1/4 inches overall in a 2-pass arrangement. That works out to about 379 square feet of heat transfer surface on 5/8-inch O.D. tubes. Standard construction uses cast iron bonnets, steel shell, copper tubes, and steel tubesheets. Design ratings run to 150 PSI on the shell side, 150 PSI on the tube side, and 375°F maximum temperature. This build is designated 5-151-16-096-002.