| Product | Style | Ratings | Configuration |
|---|---|---|---|
| Heat Exchanger | Shell & Tube | 125 PSI / 375°F | One Pass |
-Download Datasheet
Note: Unit pictured is representative of standard unit and may not exactly depict p/n 5-151-12-072-001 as shown on this page.
A removable straight-tube bundle gives 5-151-12-072-001 the thermal and mechanical margin expected of OC straight tube equipment in general industrial liquid-to-liquid heat transfer. An internally packed floating rear tubesheet absorbs differential expansion, and the bundle pulls for straight-through mechanical tube cleaning. Dimensionally it is a 12-inch shell unit, 72-inch shell length, and roughly 83-1/4 inches overall in a 1-pass arrangement. That works out to about 192 square feet of heat transfer surface on 5/8-inch O.D. tubes. As furnished, materials include cast iron bonnets, steel shell, copper tubes, and steel tubesheets. Operating limits are 125 PSI on the shell side, 125 PSI on the tube side, and 375°F maximum temperature. Installations range across condenser and evaporator service, chemical and refinery duty, and process heating and cooling.