| Product | Style | Ratings | Configuration |
|---|---|---|---|
| Heat Exchanger | Shell & Tube | 125 PSI / 375°F | One Pass |
-Download Datasheet
Note: Unit pictured is representative of standard unit and may not exactly depict p/n 5-151-08-072-001 as shown on this page.
Configured for general industrial liquid-to-liquid heat transfer, 5-151-08-072-001 carries the removable straight-tube bundle construction that defines the OC straight tube range. An internally packed floating rear tubesheet absorbs differential expansion, and the bundle pulls for straight-through mechanical tube cleaning. Physically, the unit runs a 8-inch shell, 72-inch shell length, and roughly 81-5/8 inches overall in a 1-pass arrangement. That works out to about 74.4 square feet of heat transfer surface on 5/8-inch O.D. tubes. As furnished, materials include cast iron bonnets, steel shell, copper tubes, and steel tubesheets. Operating limits are 125 PSI on the shell side, 125 PSI on the tube side, and 375°F maximum temperature. Typical duty includes condenser and evaporator service, chemical and refinery duty, and oil and quench cooling.