| Product | Style | Ratings | Configuration |
|---|---|---|---|
| Heat Exchanger | Shell & Tube | 150 PSI / 375°F | Two Pass |
-Download Datasheet
Note: Unit pictured is representative of standard unit and may not exactly depict p/n 5-267-06-060-001 as shown on this page.
This configuration is a Diamondback DSU/DWU unit built on a double-wall U-tube bundle for liquid-to-liquid transfer with cross-contamination protection. Each tube is vented to atmosphere through a diamond-pattern air gap, so a failure in either wall reports itself outside the unit. The configuration measures 6 inches across the shell, 60-inch shell length in a 2-pass arrangement. It carries 3/4-inch O.D. tubes. As furnished, materials include cast iron bonnets, steel shell, copper (double wall) tubes, and naval brass tubesheets. Operating limits are 150 PSI on the shell side, 150 PSI on the tube side, and 375°F maximum temperature. The series sees regular use in process cooling where mixing cannot be tolerated, potable water heating and cooling, and domestic water systems under double-wall codes. This build is designated 5-267-06-060-001.