| Product | Style | Ratings | Configuration |
|---|---|---|---|
| Heat Exchanger | Shell & Tube | 300 PSI / 300°F | Four Pass |
-Download Datasheet
Note: Unit pictured is representative of standard unit and may not exactly depict p/n CHXS514-4S as shown on this page.
Built around a fixed-tubesheet bundle, CHXS514-4S delivers compact liquid cooling in corrosive service for demanding service. It shares the compact CHX envelope while targeting service that would attack a standard cooler. The configuration measures 5 inches across the shell, 14-inch shell length, and roughly 18-3/8 inches overall in a 4-pass arrangement. That works out to about 9.1 square feet of heat transfer surface on 3/4-inch O.D. tubes. Material selection covers cast iron bonnets, steel shell, copper tubes, and brass tubesheets. On the ratings side, expect 300 PSI on the shell side, 150 PSI on the tube side, and 300°F maximum temperature. Installations range across deionized and treated water cooling, hydraulic and lube oil cooling, and mechanical seal cooling.