| Product | Style | Ratings | Configuration |
|---|---|---|---|
| Heat Exchanger | Shell & Tube | 300 PSI / 300°F | One Pass |
-Download Datasheet
Note: Unit pictured is representative of standard unit and may not exactly depict p/n 5-160-08-096-002 as shown on this page.
Configured for compact liquid cooling in corrosive service, 5-160-08-096-002 carries the fixed-tubesheet bundle construction that defines the CHXS compact range. It shares the compact CHX envelope while targeting service that would attack a standard cooler. The configuration measures 8 inches across the shell, 96-inch shell length in a 1-pass arrangement. It carries 3/4-inch O.D. tubes. The build specifies cast iron bonnets, steel shell, copper tubes, and brass tubesheets. The unit is rated for 300 PSI on the shell side, 150 PSI on the tube side, and 300°F maximum temperature. Common applications are deionized and treated water cooling, mechanical seal cooling, and hydraulic and lube oil cooling. Stainless construction is available throughout the wetted path for aggressive or high-purity fluids; confirm the material schedule against the order.