| Product | Style | Ratings | Configuration |
|---|---|---|---|
| Heat Exchanger | Shell & Tube | 300 PSI / 300°F | One Pass |
-Download Datasheet
Note: Unit pictured is representative of standard unit and may not exactly depict p/n 5-160-03-014-002 as shown on this page.
Configured for compact liquid cooling in corrosive service, 5-160-03-014-002 carries the fixed-tubesheet bundle construction that defines the CHXS compact range. It shares the compact CHX envelope while targeting service that would attack a standard cooler. Physically, the unit runs a 3-inch shell, 14-inch shell length, and roughly 17-1/4 inches overall in a 1-pass arrangement. That works out to about 4.3 square feet of heat transfer surface on 5/8-inch O.D. tubes. Material selection covers cast iron bonnets, steel shell, copper tubes, and brass tubesheets. The unit is rated for 300 PSI on the shell side, 150 PSI on the tube side, and 300°F maximum temperature. Installations range across mechanical seal cooling, hydraulic and lube oil cooling, and deionized and treated water cooling.