| Product | Style | Ratings | Configuration |
|---|---|---|---|
| Heat Exchanger | Shell & Tube | 300 PSI / 300°F | Two Pass |
-Download Datasheet
Note: Unit pictured is representative of standard unit and may not exactly depict p/n CHX314-2L as shown on this page.
Built around a fixed-tubesheet bundle, this configuration delivers compact liquid cooling for demanding service. Small-diameter tubes pack maximum surface into a short shell, keeping the mounting footprint tight. Dimensionally it is a 3-inch shell unit, 14-inch shell length, and roughly 17-1/4 inches overall in a 2-pass arrangement. That works out to about 4.3 square feet of heat transfer surface on 5/8-inch O.D. tubes. That combination is cataloged as CHX314-2L. Material selection covers cast iron bonnets, brass shell, copper tubes, and brass tubesheets. Design ratings run to 300 PSI on the shell side, 150 PSI on the tube side, and 300°F maximum temperature. Installations range across hydraulic and lube oil cooling, injection molding machine cooling, and mechanical seal cooling.