| Product | Style | Ratings | Configuration |
|---|---|---|---|
| Heat Exchanger | Shell & Tube | 300°F | One Pass |
-Download Datasheet
Note: Unit pictured is representative of standard unit and may not exactly depict p/n 5-155-06-081-003 as shown on this page.
For compressed air aftercooling, the ACA aftercooler line offers a removable straight-tube bundle design; this configuration sits within that range. Hot compressed air enters the tubes while cooling water counterflows through the shell, condensing moisture for removal downstream. Dimensionally it is a 6-inch shell unit, 72-inch shell length in a 1-pass arrangement. It carries 1/4-inch O.D. tubes. That combination is cataloged as 5-155-06-081-003. As furnished, materials include cast iron bonnets, steel shell, copper tubes, and steel tubesheets. Operating limits are 300°F maximum temperature. Common applications are moisture and oil removal from plant air, compressor discharge aftercooling, and pneumatic tool and instrument air conditioning. A floating rear tubesheet lets the bundle expand freely and pull for cleaning, and full-size air connections hold pressure drop down.